Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Acta odontol. latinoam ; 32(3): 141-146, Dec. 2019. graf
Article in English | LILACS | ID: biblio-1130719

ABSTRACT

ABSTRACT This study evaluated enamel mineral content and surface microhardness before and after bleaching treatment using 10% carbamide peroxide (CP) containing calcium (Ca) or amorphous calcium phosphate (ACP). Thirty-six bovine slabs were randomly allocated into 3 groups (n = 12) according to bleaching treatment: G1 - Opalescence PF 10% (CP), G2 -NiteWhite ACP (CP+ACP), and G3 - Opalescence PF (10%) with calcium (CP+CA). The bleaching agent was applied on enamel surface for 6 h/day over a period of 21 days. Enamel surface was evaluated by Knoop microhardness (KNH) and micro energy-dispersive X-ray fluorescence spectrometry (p-EDXRF) at baseline and at after bleaching treatment. Data were statistically analyzed by repeated measures ANOVA and Tukey's test (a = 0.05). There was a significant decrease in microhardness after bleaching treatments for all study groups, but no difference between bleaching gels. There was no difference in the Ca/P ratio measured by p-EDXRF for all groups at the study times, but the mean value was lower in group CP+CA than in group CP+ACP. Group CP was similar to both CP+ACP and CP+CA. It can be concluded that enamel microhardness decreased after the bleaching process, regardless of the presence of calcium or ACP, but there was no significant change in the Ca/P ratio of enamel after bleaching for each tested gel. This indicates that the bleaching gels have erosive potential, causing softening of enamel without promoting surface loss, regardless of the presence of calcium of ACP ions.


RESUMO Este estudo avaliou o conteúdo mineral do esmalte e a microdureza superficial antes e após o tratamento clareador, utilizando peróxido de carbamida 10% (PC) contendo cálcio (Ca) ou fosfato de cálcio amorfo (ACP) em sua composigao. Trinta e seis espécimes de esmalte bovino foram alocados aleatoriamente em 3 grupos (n = 12) de acordo com os tratamentos clareadores: G1 - Opalescence PF 10% (CP), G2 -NiteWhite (CP+ACP); e G3 - Opalescence PF (10%) com cálcio (CP + CA). O agente clareador foi aplicado na superficie do esmalte por 6 h/dia por um periodo de 21 dias. A superficie do esmalte foi avaliada por microdureza Knoop (KNH) e espectrometria de fluorescencia de raios X micro-dispersiva (p-EDXRF) no inicio e após o tratamento clareador. Os dados foram analisados estatisticamente pelo teste ANOVA de medidas repetidas e Tukey (a = 0,05). Houve uma diminuigao significativa da microdureza após os tratamentos clareadores para todos os grupos estudados, mas nao houve diferenga entre os diferentes géis. Nao houve diferenga da relagao Ca/P mensurada por p-EDXRF para todos os grupos nos tempos estudados; no entanto, o grupo CP+CA apresentou menor valor comparado ao grupo CP+ACP. O grupo CP foi similar aos grupos CP+ACP e CP+CA. Portanto, pode-se concluir que houve redugao significativa da microdureza do esmalte após o clareamento, independente da presenga de cálcio ou APC na composigao dos géis, embora nao tenha havido alteragao significando na relagao Ca/P do esmalte após o clareamento. Isto indica um potencial erosivo dos géis clareadores, causando o amolecimento sem perda da estrutura do esmalte, independente da presenga dos íons cálcio e ACP.


Subject(s)
Animals , Cattle , Calcium Phosphates/pharmacology , Calcium/therapeutic use , Tooth Demineralization/chemically induced , Dental Enamel/drug effects , Tooth Bleaching Agents/pharmacology , Carbamide Peroxide/pharmacology , Tooth Bleaching/methods , Tooth Remineralization , Urea/therapeutic use , Random Allocation , Dental Enamel/anatomy & histology , Hardness , Hydrogen Peroxide/therapeutic use
4.
Acta odontol. latinoam ; 23(2): 105-110, Sept. 2010. tab
Article in English | LILACS | ID: biblio-949646

ABSTRACT

Color matching in the anterior superior incisor region (ASIR) is very difficult when using a rubber dam during restorative procedures. This study measured temperature/relative humidity parameters in the ASIR and evaluated the influence of the inhalation/ downtime/exhalation mouth-breathing cycle on microleakage in composite resin restorations performed in the region, using three different adhesive systems. Sixty bovine incisors were randomly assigned to six groups (n=10) according to environmental conditions (laboratory environment or intraoral conditions) and the three adhesive systems being tested (Prime & Bond NT (PB), Single Bond (SB) and Clearfil SE Bond (CL)). The composite resin restored specimens were thermocycled (800 cycles, 5-55°C), immersed in a 2% methylene blue-buffered solution and sectioned longitudinally. The dye penetration on the margin of the restoration was evaluated and non-parametric statistical analyses were performed. The temperature and humidity parameters in the ASIR showed significant differences when compared to the laboratory environment. Restorations performed in the ASIR environment showed no increases in microleakage. As it was shown that temperature/ humidity in ASIR do not affect marginal sealing in direct composite resin restorations negatively, better color matching can be safely achieved without the use of a rubber dam.


A selecao de cor na regiao dos incisivos superiores (RIS) e muito dificil quando se utiliza isolamento absoluto durante o procedimento restaurador. O objetivo deste trabalho foi mensurar os parametros de temperatura e umidade relativa na RIS e avaliar a influencia do ciclo de inspiracao e expiracao na microinfiltracao de restauracoes em resina composta realizadas na RIS, utilizando tres sistemas adesivos. Sessenta incisivos bovinos higidos foram distribuidos, aleatoriamente, em seis grupos (n=10) de acordo com as condicoes ambientais (laboratorial ou condicao intraoral) e um dos tres sistemas adesivos testados (Prime & Bond NT (PB), Single Bond (SB) and Clearfil SE Bond (CL)). Os especimes restaurados com resina composta foram termociclados (800 ciclos, 5-55°C), imersos em solucao de azul de metileno a 2% e seccionados longitudinalmente. A penetracao de corante ao longo da margem da restauracao foi mensurada e analisada estatisticamente usando testes nao parametricos. Os parametros de temperatura e umidade relativa em RIS foram significativamente diferentes quando comparados aos encontrados em condicoes laboratoriais. As restauracoes realizadas em RIS nao apresentaram aumento na infiltracao marginal, quando comparadas as restauracoes executadas em laboratorio. Como as condicoes de temperatura e umidade intraoral nao apresentaram efeito negativo no selamento marginal de restauracoes em resina composta, a nao utilizacao do uso de isolamento absoluto pode ser considerada quando restauracoes esteticas em dentes anteriores forem realizadas.


Subject(s)
Animals , Cattle , Composite Resins , Dental Leakage , Temperature , Humidity
5.
Acta odontol. latinoam ; 23(2): 164-169, Sept. 2010. ilus, tab
Article in English | LILACS | ID: biblio-949656

ABSTRACT

This study evaluated the effect of retentive areas on onlay preparations on the dimensional alterations in condensation and addition silicone materials. A standard model with an onlay preparation was made. Each impression material was used through the double or simultaneous impression technique (n=25), resulting in a hundred impressions of the same model. Impressions were poured with type IV dental stone. Digital images were taken with a light microscope and the distances between the reference points created on the plaster dies were compared with the ones on the standard model. In the occlusal, mesial-medium and mesial-cervical segments, the double impression (DI) with condensation silicone presented similar values compared to the standard model. The values of the addition silicone with DI were similar to the standard model only in the mesial-occlusal segment. In the other segments (distal-cervical, distal-medium and distal-occlusal), all groups were statistically different from the control. It could be concluded that addition and condensation silicone impressions provided plaster dies with significant dimensional alterations in most of the evaluated areas when compared to the standard model. The retentive areas related to the onlay preparation influenced the dimensional stability of the addition and condensation silicone impressions.


Este estudo avaliou as alteracoes dimensionais de silicones de condensacao e adicao usados em duas tecnicas como resultado de areas retentivas de preparos do tipo onlay. Um modelo padrao foi feito e vinte e cinco moldagens realizadas com os dois materiais, atraves da tecnica de dupla impressao ou impressao simultanea, e cada material resultou em 50 modelos de gesso. Imagens digitais foram feitas com um microscopio de luz e as distancias entre os pontos de referencia criados no modelo de gesso foram comparados aos pontos de referencia no modelo padrao. Nos segmentos oclusais, medio-mesial e cervico-mesial, a tecnica de dupla impressao (DI) com silicone de condensacao apresentou valores similares comparados ao modelo padrao. Os valores do silicone de adicao com DI foram similares ao modelo padrao somente no segmento mesio-oclusal. Nos outros segmentos (disto-cervical, medio-distal e disto-oclusal), todos os grupos foram estatisticamente diferentes do controle. Pode- se concluir que moldagens com silicone de adicao e condensacao conferem modelos de gesso com alteracoes dimensionais significativas na maioria das areas avaliadas, quando comparadas ao modelo padrao. As areas retentivas relacionadas ao preparo de onlay influenciaram na estabilidade dimensional das moldagens atraves dos silicones de condensacao e adicao.


Subject(s)
Silicones , Dental Impression Materials , Inlays
6.
Acta odontol. latinoam ; 22(3): 171-176, 2009. ilus, tab, graf
Article in English | LILACS | ID: lil-585591

ABSTRACT

This study evaluated the bonding compatibility between dualcuredresin cements and simplified adhesive systems (one-step self-etch and two-step etch & rinse), measured after 24 hours and 3 months. The occlusal dentin surfaces of 24 human third molars were exposed and flattened. Teeth were randomly assigned to 3 groups and treated with different combinations ofadhesive system and resin cement [G1 - Single Bond/Rely X ARC (SB/RX); G2 - Excite DSC/Variolink II (EX/VR); G3 -Adper Prompt/Rely X ARC (AD/RX)]. Indirect composite restorations were cemented on flattened surfaces, and sectioned to obtain multiple bonded beams for the microtensile bond strength test. The beams from each tooth were tested under tension after 24 hours and 3 months (ANOVA/ Tukey’s test, α=5%). Failure patterns were evaluated with scanning electron microscopy. After 24h, AD/RX presented the lowest bond strength mean values. AD/RX specimens did not withstandthree months storage. SB/RX and EX/VR presented similar bond strengths in both periods tested. The associationAD/RX resulted in low bond strength mean values, especially after storage. Cementing indirect restorations using one-step self-etch adhesive systems and dual-cured resin cements wouldbe clinically unreliable.


Este estudo avaliou a compatibilidade de união entre cimentos resinosos de dupla polimerização e sistemas adesivos simplificados (adesivo autocondicionante - 1 passo- e adesivo total-each - 2 passos), após 24h e 3 meses. A superfície oclusal de 24 terceiros molares humanos foi exposta e planificada. Os dentes foram aleatoriamente divididos em 3 grupos usados de acordo a seguinte combinação entre sistema adesivo/cimento resinoso [G1 - Single Bond/Rely X ARC (SB/RX); G2 - Excite DSC/Variolink II (EX/VR); G3-Adper Prompt/Rely X ARC (AD/RX)]. Restaurações indiretas em resina composta foram cimentadas na superfície dentinária, e seccionados em múltiplos palitos para a realização do teste de resistência de união através do ensaio de microtração. Os palitos obtidos por dente foram submetidos ao teste após 24 horas e 3 meses (ANOVA/ Tukey test, α=5%). O padrão de fraturafoi observado no microscópio eletrônico de varredura. Após 24 horas, AD/RX apresentou menor valor médio de resistência de união. Os corpos-de-prova do grupo AD/RX não resistiram aoarmazenamento de 3 meses. SB/RX e EX/VR demonstraram similarresistência de união em ambos os períodos avaliados. A associação AD/RX resultou em menores valores médios deresistência de união, especialmente após o armazenamento. A cimentação de restaurações indiretas utilizando sistemas autocondicionantes (1 passo) e cimentos resinosos de dupla polimerização não foi considerada clinicamente confiável.


Subject(s)
Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Dentin , Dental Bonding/methods , Compressive Strength , Microscopy, Electron, Scanning/methods , Data Interpretation, Statistical
SELECTION OF CITATIONS
SEARCH DETAIL